Fluke 572-2 High Temperature Infrared Thermometer is perfect for measuring temperatures in unreachable places. Let the measuring area be an air duct on the ceiling of a warehouse or a transformer on the top of a power pole, the dual laser setting will clearly show you the diameter of the area you are measuring.
Features of Fluke 572-2 High Temperature Infrared Thermometer:
- An ultra-high 60:1 distance-to-spot ratio with dual laser sighting for fast, accurate targeting
- Features a user-selectable multi-language interface
- MAX, MIN, DIF, AVG temperature can also be displayed
- Provides adjustable emissivity and a predefined emissivity table
- Audible and visible alarms for rapid detection of high and low temperatures outside the limits
- 99 data sets can be stored for review and analysis
- Presents infrared and thermocouple temperatures on a bright backlit display
- Standard mini-connector K-type thermocouples compatibility
- Features last reading Hold (20 seconds)
Additional Information
Weight | 1 kg |
---|---|
Manufacturer | Fluke |
Model No | 572-2 |
Measuring Parameters | Infrared Temperature |
Range | -30°C to 900°C (-22°F to 1652°F) |
Accuracy_1 | ≥ 0°C: ± 1°C or ± 1% of the reading, whichever is greater |
Resolution_1 | 0.1°C, 0.1°F. |
Distance to spot ratio | 60:1 (calculated at 90 % energy) |
Minimum spot size | 19 mm |
Laser sighting | Offset dual laser, output <1 mW |
Spectral Response | 8 μm to 14 μm |
Response Time | < 500 ms |
Emissivity | Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials |
Repeatability | ±0.5% of reading or ±0.5°C (±1°F), whichever is greater |
Measurement range (K-type thermocouple bead probe) | -40 °C to 260 °C (-40 °F to 500 °F) |
Accuracy_2 | ± 1.1 °C (± 2.0 °F) from 0 °C to 260 °C (32 °F to 500 °F). Typically within 1.1 °C (2.0 °F) from -40 °C to 0 °C (-40 °F to 32 °F) |
K-type thermocouple input temperature range | -270 °C to 1372 °C (-454 °F to 2501 °F) |
K-type thermocouple input accuracy (with ambient temperature 23 °C ± 2 °C) | < -40 °C: ± (1 °C + 0.2 °/1 °C) ≥ -40 °C: ± 1 % or 1 °C, whichever is greater < -40 °F: ± (2 °F + 0.2 °/1 °F) ≥ -40 °F: ± 1 % or 2 °F, whichever is greater |
K-type thermocouple resolution | 0.1 °C/0.1 °F |
K-type thermocouple repeatability | ± 0.5 % of reading or ± 0.5 °C (± 1 °F), whichever is greater |
Cable Length | 1 m (40 in) K-type thermocouple cable with standard miniature thermocouple connector and bead termination |
Operating Temperature | 0°C to +50°C (+32°F to +122°F) |
Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
Relative Humidity | 10% to 90% RH non-condensing up to 30°C (86°F) |
Operating Altitude | 2000 meters above mean sea level |
Safety and compliance | IEC 60825-1 FDA Laser Class II EMC 61326-1 CE Compliance CMC |
Battery | 2 AA batteries |
Warranty | 2 Years Manufacturing Warranty |
Weight | 322 Grams |