Fluke 1621 Earth Ground Tester

80,634.00

Fluke 1621 is an easy-to-use earth ground tester. For ground resistance testing, the 1621 is the first line of defense in detecting reliable ground connections. The unit features basic ground testing methods including 3-pole Fall-of-Potential as well as 2-pole ground resistance tests.

Features:

• 3-pole Fall-of-Potential earth testing for basic measurements

• 2-pole resistance measurements for added versatility

• Easily capture values with single-button operation

• Ensure accurate measurements with automatic ‘noise’ voltage detection

• Hazardous voltage warning offers increased user protection

• Clearly read and record data with a large, backlit display

In Stock

100 in stock


Ask a question?
Click here to reach our experts

Free shipping all over India

Product Description

Fluke 1621 Earth Ground Tester’s convenient size, rugged holster, and large, clear LCD display make it an ideal field earth ground tester, for most electrical grounding work environments. With a simple user interface and intuitive functionality, the Fluke 1621 is a handy grounding tool for electrical contractors, utility test engineers, and earth ground specialists.

Measuring range

 

0.15 Ω to 20 Ω

 

Resolution

 

 0.01 Ω

Display range

 

 0 to 19.99 Ω

200 Ω

 

Resolution

 

 0.1 Ω

Display range

 

 20 to 199.9 Ω

2 kΩ

 

Resolution

 

 1 Ω

Display range

 

 200 to 1999 Ω

Intrinsic uncertainty

 

 ± (6 % of measured value + 5D)

Operating uncertainty IEC 61557[1]

 

 ± (18 % of measured value + 5D)

Notes:

 

 [1] Covers all deviations caused by influence quantities E1-E5.
If the deviation E4 caused by high probe or auxiliary probe resistance is higher than specified flashes.
Measured values are outside of the specified operating uncertainty.

Electrical specifications

 

Maximum deviations:

 

E1 Influence factor

 

 Position

E1 Deviation influence

 

 0 %

E2 Influence factor

 

 Supply voltage

E2 Deviation influence

 

 0 %

E3 Influence factor

 

 Temperature E3

E3 Deviation influence

 

 2.3 %

E4 Influence factor

 

 Serial interference voltage (20 V)

E4 Deviation influence

 

 0.6 %

E5 Influence factor

 

 Probe- and auxiliary probe resistance

E5 Deviation influence

 

 10 %

Test voltage

 

 3.7 kV

Protection type

 

 IP 40; IEC/EN 60529

Electromagnetic compatibility

 

 Emission: IEC/EN 61326 Class B

 Immunity: IEC/EN 61326 Annex C

RE resistance measurement

 

Measuring method

 

 Current-voltage measurement with improved cross-talk attenuation, no compensation of measuring lead resistance, with probe (3-pole) or without probe (2-pole), as per IEC/EN 61557-5

Open circuit voltage

 

 23 to 24 V ac

Short circuit current

 

 > 50 mA ac

Measuring frequency

 

 128 Hz

Maximum permissible overload

 

 250 Veff

Measuring time

 

 8 seconds (average from when START is pressed)

Limit input

 

 Tester retains set value even if instrument is turned off (assuming battery power supply is sufficient)

Automatic changeover of resolution

 

RH

 

 < 7 kΩ

Resolution

 

 0.01 Ω

RH

 

 < 50 kΩ

Resolution

 

 0.1 Ω

RH

 

 > 50 kΩ

Resolution

 

 1 Ω

Interference voltage display dc + ac

 

Vmax

 

 30 Veff

Common mode rejection

 

 > 80 dB at 50 Hz and 60 Hz

Ri

 

 680 kΩ

Measuring uncertainty

 

 < 10 % for pure ac and dc signals

General specifications

 

Measuring functions

 

 3-pole earth ground resistance, 2-pole ac resistance of a conductor, Interference voltage

Intrinsic error

 

 Refers to the reference temperature range and is guaranteed for one year

Measuring rate

 

 2 measurements/second

Battery[1]

 

 One 9 volt alkaline (LR61)

Battery condition

 

 LO-BAT is displayed if voltage drops below 6.5 V

Voltages

 

Between jacks H/C2 and E/C1:

 

 250 Veff maximum (effective voltage)

Between jacks S/P2 and E/C1:

 

 250 Veff maximum

Climatic class

 

 VDE/VDI 3540 RZ (conforming to KWG as per DIN 40040, 4/87)

Temperature performance[2]

 

Working:

 

 -10 °C to +50 °C (+14 °F to +122 °F)

Operating:

 

 0 °C to +35 °C (+32 °F to +95 °F)

Storage:

 

 -20 °C to +60 °C (+68 °F to +140 °F)

Reference:

 

 +23 °C ± 2 °C (+73 °F ± 4 °F)

Temperature coefficient

 

 ± 0.1 % of range per degree Kelvin

Safety

 

 IEC/EN 61010-1, 600 V CAT II, pollution degree 2

Dimensions

 

 113 mm x 54 mm x 216 mm (4.5 in x 2.1 in x 8.5 in), including holster

Weight

 

 850 g (1.9 lb), including standard accessories, volume approximately 600 cm3

Note:

 

 [1]If the tester is not going to be used, or is being stored for a long period, remove the battery and store separately from the tester to avoid damage from battery leakage.

Note:

 

 [2]The four temperature ranges for the tester exists to satisfy European Standards requirements; the instrument can be used over the full working temperature range by using the temperature coefficient to calculate accuracy at the ambient temperature of use.

Additional Information

Weight0.56 kg
Manufacturer

Model

There are no reviews yet.