Dwyer CDT-5D40 Carbon Dioxide Transmitter
₹15,263.99
(GST 18% Exclusive)
Dwyer CDT Series Carbon Dioxide and Temperature Transmitters measure the concentration and temperature of CO2 in schools, office buildings and other indoor environments to help achieve LEED ® certification. For improved sensor longevity, a single-beam dual-wavelength non-dispersive infrared (NDIR) sensor is used to automatically correct aging effects in both occupied and unoccupied buildings.
Applications: Demand control ventilation in schools, office buildings, hospitals, and other indoor environments
Customers who bought this item also bought
-
₹9,970.34
(GST 18% Exclusive)
Senseair Carbon Dioxide (CO2) Transmitter
-
(GST 18% Exclusive)
Drager Pac 8000 Portable CO₂ Gas Detector
-
₹15,929.66
(GST 18% Exclusive)
Honeywell CDS2000A1000C Carbon Dioxide Gas Detector
-
₹20,468.00
(GST 18% Exclusive)
Lutron GC-2028 Carbon Dioxide Meter
Dwyer CDT Series Carbon Dioxide and Temperature Transmitters measure the absorption of CO2 and temperature indoor areas to ensure energy savings. For greater sensor precision, a single beam dual-wavelength nondispersive infrared (NDIR) system is mostly used to automatically correct the measurement towards light source aging effects both in occupied * and unoccupied building structures. Similar to Automatic Baseline Correction methods, the single-beam dual-wavelength sensor technology offers the highest degree of precision and can accidentally change the calibration based on CO2 levels and barometric pressure.
Features of Dwyer CDT-5D40 Carbon Dioxide Transmitter :
- Single beam dual-wavelength NDIR sensor eliminates draft due to light source aging
- Optional integral display and relay output
- Integral passive temperature outputs reduce the number of devices mounted in the space
- Service display tool available for models without an integral LED
Additional information
Weight | 1 kg |
---|---|
Manufacturer | Dwyer |
Model No. | CDT-5D40 |
Measuring Parameters | CO2 and temperature |
Range | 0 to 2000 or 0 to 5000 ppm |
Accuracy | ±40 ppm ±3% of reading |
Pressure Dependence | 0.13% of reading per mm of Hg. |
Range_1 | 32 to 122°F (0 to 50°C) |
Accuracy_1 | ±1°C @ 25°C |
Temperature Dependence | ±8 ppm/°C at 1100 ppm |
Current Output | 4 to 20 mA (max. 500 Ω |
Voltage Output | 0 to 5 VDC or 0 to 10 VDC |
Relay Output | SPST NO rated 2 A @ 30 VDC |
Operating Temperature | 32 to 122°F (0 to 50°C). |
Operating Humidity | 10 to 95% RH (non-condensing) |
Enclosure Rating | Duct mount: NEMA 4X (IP66) for housing only; Wall mount: IP20 |
Weight | 4.4 oz (125 g). |
Reviews