Dwyer CDT-2D40 Duct Mount Carbon Dioxide Transmitter

14,575.42

(GST 18% Exclusive)

In stock

Product Id: 157753

Dwyer CDT-2D40 Duct Mount Carbon Dioxide Transmitter accurately monitors the CO2 concentration in indoor environments to help achieve energy savings. For increasing sensor accuracy, a single-beam dual-wavelength nondispersive infrared (NDIR) sensor is used to automatically correct the measurement in both occupied and unoccupied buildings against light source aging effects.
Application: Demand control ventilation in schools, office buildings, hospitals, and other indoor environments

Add to Cart
Request to Quote Image

Dwyer CDT-2D40 Duct Mount Carbon Dioxide Transmitter is  Single-beam dual-wavelength sensor technology provides the user the highest level of accuracy when compared to Automatic Baseline Correction methods which can unintentionally shift the calibration based on CO2 levels and barometric pressure condition. In order to achieve a higher level of accuracy, the CDT includes digital barometric pressure adjustment and the ability to field-calibrate the sensor. The Push buttons are standard on all configurations of the transmitters.

Features of Dwyer CDT-2D40 Duct Mount Carbon Dioxide Transmitter : 

  • Single beam dual-wavelength NDIR sensor eliminates draft due to light source aging
  • Integral passive temperature outputs reduce the number of devices mounted in the space
  • Service display tool available for models without an integral LED
  • Optional integral display and relay output

Additional information

Weight 1 kg
Manufacturer

Dwyer

Model No

CDT-2D40

Product Series

CDT Series

CO2 Measuring Range

0 to 2000 or 0 to 5000 ppm

Accuracy

±40 ppm

Temperature Range

0 to 50°C

Accuracy_1

±1°C @ 25°C

Sensors

Single beam, dual wavelength NDIR

Temperature Dependance

±8 ppm/°C at 1100 ppm.

Pressure dependency

0.13% of reading per mm of Hg

Non Linearity

16 ppm

Response Time

2 min for 99% step change.

Operating Temperature

0 to 50°C

Operating Humidity

10 to 95% RH (noncondensing)

Duct Air Velocity Range

0 to 4000 FPM
(20.32 m/s).

Power Consumption

Average: 2 w; Peak: 3.75 w.

Output

Current: 4 to 20 mA (max. 500 Ω); Voltage: 0 to 5 VDC or 0 to 10 VDC (min. 500 Ω); Relay: SPST NO rated 2 A @ 30 VDC.

Power Requirements

16 to 35 VDC or 19 to 28 VAC

Dimension

4-25/32" x 11-49/64"

Weight

125 Grams

Be the first to review “Dwyer CDT-2D40 Duct Mount Carbon Dioxide Transmitter”

Reviews

There are no reviews yet.

CDT-2D40

Dwyer CDT-2D40 Duct Mount Carbon Dioxide Transmitter

14,575.42

(GST 18% Exclusive)

Add to Cart