Metravi PM 29 Digital Process Meter(DMM+CALIBRATOR)

45,505.00

(GST 18% Exclusive)

In stock

Product Id: 156844

Metravi PM 29 Digital Process Meter/Calibrator is a Process Calibrator cum Multimeter used to measure and source various parameters like AC/DC Current, AC Voltage, Frequency, RTD measurements, diode, and continuity testing with IEC 61010 rating.

Applications: Electrical and electronics industries, to verify test installations and instrumentation.

Add to Cart
Request to Quote Image

Features of Metravi PM 29 Digital Process Meter:

In Measure Mode:

  • DC Voltage: 0 – 4 / 40 / 400V Accuracy of ±0.2%
  • DC Milli Volt: 0 – 40m / 400mV Accuracy of ±0.2% 
  • AC Voltage :  0 – 400m / 4 / 40 / 400V Accuracy of ±0.2%
  • DC Current : 0 – 40m / 400mA Accuracy: ±0.2%
  • AC Current: 0 – 40m / 400mA Accuracy: ±0.5%
  • Resistance: 0 – 400 / 4k / 40k / 400k / 4M / 40M.Ohms  Accuracy:  ±0.2%
  • Frequency: 0 – 50 / 500 / 5k / 50k / 100kHz Accuracy: ±0.1%
  • Temperature through PT-100 Sensor: -200°C to 700°C Accuracy:  ±0.5%
  • Temperature through Cu-50 Sensor: -50°C to 150°C Accuracy: ±0.5%
  • Temperature through R type Sensor: -40°C to 1760°C Accuracy: ±0.5%
  • Temperature through S type Sensor: -20°C to 1760°C Accuracy: ±0.5%
  • Temperature through B type Sensor: 400°C to 1800°C Accuracy: ±0.5%
  • Temperature through E type Sensor: -200°C to 500°C Accuracy: ±0.5%
  • Temperature through K type Sensor: -200°C to 950°C Accuracy: ±0.5%
  • Temperature through J type Sensor: -200°C to 700°C Accuracy: ±0.5%
  • Temperature through T type Sensor: -200°C to 400°C Accuracy: ±0.5%
  • Temperature through N-type Sensor: -200°C to 1000°C Accuracy: ±0.5%
  • Diode Test and Continuity Test Facility

In the source mode:

  • Resistance: 0 – 400 Ohms Accuracy: ±0.5%
  • DC Milli Volt: -10 – 100mV Accuracy: ±0.5% 
  • DC Voltage: -0.5 to 5.5V Accuracy: ±0.2%
  • Frequency: 0 – 100 / 1k / 10kHz Accuracy: ±0.2%
  • XMT in the range: 0 to -20mA Accuracy: ±0.2%
  • DC Milli Ampere: 0 to 22mA Accuracy: ±0.2% 
  • Temperature output for Pt-100 Sensor: -200°C to 850°C Accuracy: ±0.5%
  • Temperature output for Cu-50 Sensor: -50°C to 150°C Accuracy: ±0.5%
  • Temperature output for R type Sensor: -40°C to 1760°C Accuracy: ±0.5%
  • Temperature output for S type Sensor: -20°C to 1760°C Accuracy: ±0.5%
  • Temperature output for B type Sensor: -40°C to 1800°C Accuracy: ±0.5%
  • Temperature output for E type Sensor: -200°C to 1000°C Accuracy: ±0.5%
  • Temperature output for K type Sensor: -200°C to 1370°C Accuracy: ±0.5%
  • Temperature output for J type Sensor: -200°C to 700°C Accuracy: ±0.5%
  • Temperature output for T type Sensor: -200°C to 400°C Accuracy: ±0.5%
  • Temperature output for N-type Sensor: -200°C to 1300°C Accuracy: ±0.5%

Additional information

Weight 1 kg
Manufacturer

Metravi

Model No

PM-29

Measuring Parameters

AC Current, AC Voltage, DC Current, DC mV, DC Voltage, Frequency, Resistance, RTD

DC Voltage

4.000V to 400.0V

Accuracy

0.2% +4

Resolution_1

0.001V

DC mV

40.00mV to 400.0mV

Accuracy_1

0.5% +6

Resolution_2

0.001 V to 0.1 V

AC Voltage

400.0mV to 400.0V

Accuracy_2

1.0% +4

Resolution_3

0.01 mV

DC Current

40.00mA to 400.0mA

Accuracy_3

0.2% +4

Resolution_4

0.01 mA

AC Current

40.00mA to 400.0mA

Accuracy_4

0.5% +4

Resolution_5

0.01mA

Resistance

400Ω to 40MΩ

Accuracy_5

0.2% +4

RTD

Pt 100 to Cu50

Accuracy_6

0.5% +2

Resolution_6

0.1 °C

Frequency

50.00Hz to 100.0Khz

Accuracy_7

0.01% +3

Resolution_7

0.01 Hz

Power Supply

6V batteries

Dimension

205 X 95 X 42 mm

Weight

500 Grams

Be the first to review “Metravi PM 29 Digital Process Meter(DMM+CALIBRATOR)”