Product Description
Kimo DBM 610 Capture Hood is the next generation flow capture hood. The large digital display reads out air volume, differential pressure, and temperature simultaneously. DBM-620 features data logging, airflow and temperature readout, and a removable flow meter display that becomes a portable test instrument. The digital display is removable, allowing it to act as a portable airflow measurement instrument with a pitot tube. It can also be used as a micro-anemometer, measuring low-level differential pressure. Kimo DBM 610 Capture Hood is an ideal solution for HVAC airflow commissioning and air balancing. Five different size flow hoods are available to check airflow volume from most diffusers and grilles.
Features of DBM 610 Capture Hood:
- 610 x 610 mm hood
- Pitot tube length 300 mm
- 2 x 1 m of silicone tube
- USB cable
- Factory Test Report
- Transport case
Additional Information
Weight | 4.1 kg |
---|---|
Manufacturer | Kimo |
Model No | DBM 610 |
Select Model | DBM 610, Standard DBM 610 |
Measuring Parameters | Air velocit, Airflow, Pressure, Atmospheric Pressure, Relative Humidity, Temperature |
Resolution | 0.001 to 0.1 Pa |
Operating Temperature | 0 to +60°C |
Storage Temperature | -20 to +70 °C |
Storage capacity | 200 datasets of 100 points |
Display | Large graphic back-lighted LCD / Sizes : 86 x 51 mm |
Power Supply | 4 alkaline batteries LR6 Rechargeable battery Li-ion 3.7 V 4400 mhA (optional) |
Auto Shutoff | Adjustable from 0 to 120 min |
Language | French, English, German, Finnish, Dutch, Italian, Norwegian, Portuguese, Slovak, Swedish, Chinese |
Airflow Measuring Range | From 35 to 4250 m3/h From 10 to 1181 L/s From 21 to 2501 CFM |
Accuracy(1) | ±3% of the measurement ±10 m3/h ±3% of the measurement ±3 L/s ±3% of the measurement ±6 CFM |
Resolution(1) | 1 m3/h 1 L/s 1 CFM |
Air velocity Measuring range | From 0.2 to 10 m/s From 39 to 1969 ft/min |
Accuracy(2) | ±3% of the measurement ±0.04 m/s ±3% of the measurement ±8 ft/min |
Resolution(2) | 1 m3/h 1 L/s 1 CFM |
Temperature(NTC) Measuring range | From -20 to 70°C-4 to 158°F |
Accuracy(3) | ±0.2°C ±0.36°F |
Resolution(3) | 0.01°C 0.01°F |
Relative humidity Relative humidity | From 0 to 100%RH |
Accuracy(4) | Repeatability, linearity: ±1.5% RH(2) (from 10 to 80% RH and from 10 to 50°C)(3) Hysteresis: 0.8% RH at 25°C Time drift: <0.5% RH per year in normal conditions of use (from 5 to 50°C and from 20 to 80% RH, apart from indoor pollutants) |
Resolution(4) | 0.01%RH |
Atmospheric pressure Measuring range | From 700 to 1100 mbar |
Accuracy(5) | ±3 mbar |
Resolution(5) | 1 mbar |
Pressure Measuring range | From -2500 to +2500 Pa From -10 to 10 inWg |
Accuracy(6) | ±0.2% of reading ±2 Pa ±0.2% of reading ±0.008 inWg |
Resolution(6) | From 0.001 to 0.1 Pa , 0.001 inWg |
Weight | 3600 Grams |
Downloads