Dwyer® 641RM-12 Series Air Velocity Transmitter
(GST 18% Exclusive)
Dwyer® 641RM-12 Series Air Velocity Transmitter is the perfect instrument for observing airflow. This transmitter utilizes a warmed mass stream sensor, which takes into consideration exact speed estimations at different stream rates and temperatures. the transmitter has a highly accurate heated mass flow sensor as the Series 641, with a remote probe construction. The unit’s 6´ cable which connects the sensing probe with the electronic enclosure allows the enclosure to be mounted where it can be more easily accessed.
Application: exhaust stack flow monitoring, Air control in drying processes, HVAC air velocity measurements, Fan supply, and exhaust tracking, Cleanroom ventilation monitoring.
Customers who bought this item also bought
-
₹14,596.00
(GST 18% Exclusive)
Dwyer® AVUL Series Air Velocity Transmitter – AVUL-5DA1-LCD
-
₹14,421.19
(GST 18% Exclusive)
Aerosense AVT Air Velocity Transmitter
-
₹53,828.81
(GST 18% Exclusive)
Rotronic AF1 Air Flow Transmitter
Dwyer® 641RM-12 Series Air Velocity Transmitter have selectable reaches from 0-250 to 15,000 FPM (0-1.25 to 75 MPS) give it the flexibility to be chosen for a large number of uses. The unit’s 6′ link which associates the detecting test with the electronic fenced-in area enables the walled-in area to be mounted where it very well maybe all the more effectively got to. Longer link lengths are accessible for channels that are at high heights from the plant floor. The discretionary LED creates an entire, conservative answer for a nearby sign of wind stream.
Features of Dwyer® 641RM-12 Series Air Velocity Transmitter :
- Ranges from 250 FPM (1.25 MPS) to 15,000 FPM (75 MPS)
- An optional bright LED display
- Easy push-button set-up
- Compact housing
- 4 to 20 mA output
- Digital filter for signal damping
Additional information
Weight | 1 kg |
---|---|
Manufacturer | Dwyer |
Select Model | 641RM-12, Air Velocity Transmitter with 6´ cable, 641RM-12-LED, Air Velocity Transmitter with 6´cable & LED Display |
Temperature | -40 to 100°C (-40 to 212°F) |
Accuracy_1 | 3% FS process gas: 32 to 122°F (0 to 50°C); 4% FS process gas: -40 to 32°F & 122 to 212°F (-40 to 0°C & 50 to 100°C). |
Output | 4-20 mA, isolated 24V source, 3 or 4-wire connection |
Current consumption | 300 mA max |
Electrical Connection | Screw terminal. |
Temperature Limits | Process: -40 to 212°F (-40 to 100°C); Ambient: 32 to 140°F (0 to 60°C). |
Mounting | Unit not position sensitive. Probe must be aligned with airflow. |
Response Time | Flow: 1.5 seconds to 95% of final value (output filter set to minimum). |
Power Requirements | 12 to 35 V DC, 10 to 16 V AC |
Length | Probe:12˝ (30.48 cm) standard. |
Cable Length | 6 ft (1.82 m). |
Loop Resistance | 600 ohms max. |
Weight | 375 Grams |