Usually ships in 1 - 2 weeksUsually ships in 1 - 2 weeks, However please contact store for precise delivery schedule. Backorder also allowed
HTTPS Secured PaymentHTTPS, the lock icon in the address bar, an encrypted website connection. While it was once reserved primarily for passwords and other sensitive data, the entire web is gradually leaving HTTP behind and switching to HTTPS.
The 'S' in HTTPS stands for 'Secure'. It’s the secure version of the standard “hypertext transfer protocol”. Most importantly, your payment is also secured.
Bulk Purchase? Reach us for special price
Free shipping all over India
Ask a question?
Product Description
ACE AI-CRM1 Hospital Clean Room Monitor is used to measure essential parameters like Temperature, Humidity, and Differential Pressure in Pharmaceutical Clean Room Applications. This Clean Room Monitor includes integrated buzzer for parameter violation
indication, individual LED for process violation
Features of ACE Hospital Clean Room Monitor :
- Flush mounting n Modular Wall or Brick Walls of Clean Rooms.
- The sensors for each of the 3 parameters are coordinates inside for convenience and installation.
- The front stainless steel plate
- Individual LED for process violation visual caution
- This OT Monitor has RS 485 Modbus correspondence for a simple combination to BMS/SCADA/EMS.
Additional Information
Weight | 1 kg |
---|---|
Manufacturer | Ace Instruments |
Model No | AI-CRM1 |
Range | 1) -30.0 to +50.0 Deg. C typical for Temperature 2) 0.0 to 100.0 %RH typical for Relative humidity 3) 0.0 to +25.0 mm. W.C./ 0 to 250 Pascals (Any other customized range as per user specifications) |
Accuracy_1 | 1) ±0.5 Deg C for -30 to 500 C for temperature 2) ±1.8% for 10 to 95% RH for relative humidity 3) ±0.5% F.S. for Differential pressure |
Resolution_1 | Fixed 0.1 for both Temperature & Relative Humidity, 0.1 mm.W.C. or 1 pascals for Differential Pressure |
Display | 3 Line Red 7 Segment LED Display of height 0.4" ; 4 Digits for Differential Pressure on Line 1 ; 4 Digits for % R.H. ( Humidity ) on Line 2 ; 4 Digits for Temperature ( Deg. C) on Line 3 |
Differential Pressure Entry | 2 Nos. 4 mm. Hose Nipples at top |
Sensors | Integrated Humidity & Temperature Sensor flushed to front plate Built in differential pressure sensor with Brass Hose Nipples (Chrome Plated) for Differential Pressure At Rear ( 4mm x 2 Nos.) Opt |
Supply voltage | 24VDC, 250mA |
Enclosure | M.S. Powder Coated Body with Stainless Steel Front Flush Plate for Modular Wall Mounting /Optional Brick Wall Mounting |
Communication | RS 485 Modbus Protocol (Optional) |
Sensor Type | 1) Polymer sensing for Temperature 2) Capacitive polymer sensing for Relative humidity 3) Piezo Resistive Sensor for Differential Pressure |
Buzzer | Integrated buzzer for Alarm in case of process violation of any of the 3 parameters |
Setting | By 4 keys on the front stainless steel panel |
Dimensions | Enclosure : 74(W) X 72(H) X 40(D) mm. Stainless Steel Front Plate : 110W x 90 (H) mm. |
Be the first to review “ACE AI-CRM1 Hospital Clean Room Monitor”